How to Disconnect Push-to-Connect Air Fittings Without Damaging Them
Share
Push-to-connect (push-in) fittings are used on air compressors, truck air lines, water filters and 3D printers. Pushing the tube in locks it in place; to take it out, you need to release the grip first. Pulling hard without releasing it damages the tube and can scratch the fitting.
How the fitting holds the tube
Inside the fitting is a ring of small stainless teeth held by a collar (the collet). When you pull on the tube, the teeth bite in harder. Pressing the collet toward the fitting body spreads the teeth so the tube can slide out.
Before you start
- Release the pressure. Turn off the compressor or supply and bleed the line. Never disconnect a pressurized air line.
- Wear eye protection in case of trapped air.
Releasing the tube
- Push the tube slightly into the fitting first.
- Hold the collet down evenly against the fitting body.
- While holding the collet, pull the tube straight out.
On larger or stiff fittings, and in tight engine bays, it is hard to press the collet evenly by hand. A release tool such as our air hose connector remover pliers presses the collet evenly with one hand, so the tube slides out without scratching.
Reconnecting
- Cut the tube end square with a tube cutter or sharp blade; angled or crushed ends can leak.
- Push the tube in firmly until it bottoms out, then tug gently to confirm it is locked.
- Check the fitting size matches your tube's outside diameter. See our 80-piece push-in fitting kit and straight air line fittings for trucks.
More garage tools in Utility Tools.